Mô tả
Function
LRG 16-41
The conductivity electrode consists of two current and
two voltage electrodes. The current electrodes send the
measuring current UI
with a fixed frequency into the fluid, thereby creating a potential gradiant between these
electrodes. This potential gradiant is then detected by the
voltage electrodes and evaluated as measuring voltage UU.
Thanks to this process insulating layers and polarization
effects will be compensated. Technical Data
Test approval no.
TÜV . WÜL . xx-007
Service pressure
LRG 16-40, LRG 16-41: 32 bar at 238 °C
LRG 17-40: 60 bar at 275 °C
End connection
Screwed 1″, ISO 228-1
Materials
Electrode screw-in body: 1.4571,
X6CrNiMoTi17-12-2
Measuring electrode(s): 1.4571, X6CrNiMoTi 17-12-2
Electrode rod insulation: PTFE
Terminal box 3.2161 G AlSi8Cu3
LRG 16-40, LRG 17-40: Measuring tube & screw 1.4571,
X6CrNiMoTi17-12-2
LRG 16-40, LRG 16-41: Spacer disks PEEK
LRG 17-40: Spacer disks PEEK HT
Temperature sensor
Resistance thermometer Pt 1000
Đánh giá